產品名稱: IKGKF-100系列,en
模型:IKGKF-100
筆記: 100W AC/DC power supply, 90Vac~264Vac input
Built-in Active PFC function, PF>0.93
Suitable for peak load application
PCB soldering side with conformal coating
Withstand 300Vac surge input for 5 secs
OLP/SCP/OPP Protections
Applications: CNC system, Industrial Robot, man-machine interface,PLC, DC motors.
MODEL |
IKGKF-100-5 |
IKGKF-100-12 |
IKGKF-100-24 |
IKGKF-100-48 |
||
OUTPUT |
DC Output |
5V |
12V |
24V |
48V |
|
Rated Current |
20一個 |
8.5一個 |
4.2一個 |
2.2一個 |
||
CurrentRange Note 1 |
0~20A |
0~8.5A |
0~4.2A |
0~2.2A |
||
Ripple and Noise Note 2 |
0~70℃ |
≤150mV |
≤150mV |
≤150mV |
≤150mV |
|
-20~0℃ |
≤150mV |
≤150mV |
≤150mV |
≤200mV |
||
Voltage ADJ. Range |
3.3V—5.5V |
10~15V |
21~27V |
43.2~52.8V |
||
Voltage Accuracy |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
||
線路調整 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
||
負載調節 |
±2.0% |
±2.0% |
±1.0% |
±1.0% |
||
Set-up Time |
≤4S @115Vac,≤2S @230Vac |
|||||
Hold up Time |
≥12mS (230Vac input, Full load) |
|||||
Temperature Coefficient |
±0.03%/℃ |
|||||
Overshoot and Undershoot |
<5.0% |
|||||
INPUT |
VoltageRange |
90Vac~264Vac |
||||
FrequencyRange |
47Hz~63Hz |
|||||
Power factor (typical) |
PF>0.98@115Vac, PF>0.93@230Vac |
|||||
Efficiency (Typical) 230Vac input |
≥84% |
≥87% |
≥88% |
≥88% |
||
AC Current (最大。) |
<1.5 A |
|||||
Inrush Current (Typical) |
<30@115Vac,<50A@230Vac Cold start |
|||||
Leakage Current |
Input—output: ≤0.25mA Input—PG: ≤3.5mA |
|||||
PROTECTION |
Over Load |
110%~150% of rated output current, hiccup mode, auto recovery |
||||
Over power |
110%~150% of rated output current, hiccup mode, auto recovery |
|||||
Short Circuit |
Long-term mode, auto recovery |
|||||
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-20℃~60℃; 20%~90%RH No condensing (refer to the derating curve) |
||||
Storage Temp. & Hum. |
-30℃~85℃; 10%~95%RH No condensing |
|||||
SAFETY &EMC Note 3 |
Safety Standards |
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 |
||||
Withstand Voltage |
Primary-Secondary:3.0KVac; ≤10mA .Primary-PG:1.5KVac; ≤10mA. Secondary-PG:0.5KVDC;≤10mA. |
|||||
Isolation Resistance |
100Mohms |
|||||
EMSEmission |
Compliance to EN55022 Class B |
|||||
Harmonic Current |
Compliance to EN61000-3-2, Class A |
|||||
EMC Immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level |
|||||
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 200,000Hrs (25℃, Full load) |
||||
Dimension (L*W*H) |
129×98.3×37.6mm |
|||||
Packing |
|
|||||
Cooling method |
Cooling by free air convection |
|||||
NOTE |
1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2.Measured at 20MHz of bandwidth 3.SPS被認為是將安裝到最終設備中的組件,,en,必須重新確認設備仍符合EMC指令,,en,Powerld為Din-35導軌提供配件,,en,請聯繫銷售人員了解詳情,,en,&nbsp;打開框架,,en. The equipment must be re-confirmed that it still meets EMC directives. |