產品名稱: IKGKF320系列,en
模型:IKGKF320
筆記: 320W AC/DC power supply
Built-in active PFC,PF>0.95
Output protection: SCP/OLP/OVP/OTP
Withstand 300Vac surge input for 5 sec
Wide operating ambient temperature (-25~70℃)
PCB both sides with conformal coating
Suitable for harsh Environment
Built in Fan speed control
199*98*50mm(L*W*H)
Applications: CNC system, Industrial Robot, man-machine interface,PLC, DC motors.
MODEL |
IKGKF-320-12II |
IKGKF-320-24II |
IKGKF-320-36II |
IKGKF-320-48II |
||
OUTPUT |
DC Output |
12V |
24V |
36V |
48V |
|
Rated Current |
25一個 |
13一個 |
8.9一個 |
6.7一個 |
||
CurrentRange Note 1 |
0~25A |
0~13A |
0~8.9A |
0~6.7A |
||
Ripple and Noise Note 2 |
0~65C |
≤200mV |
≤150mV |
≤200mV |
≤150mV |
|
-20~0C |
≤250mV |
≤200mV |
≤200mV |
≤200mV |
||
Voltage ADJ. Range |
10~15V |
20~27V |
32~40V |
42~53V |
||
Voltage Accuracy |
±2.0% |
±1.0% |
||||
線路調整 |
±0.5% |
|||||
負載調節 |
±2.0% |
±1.0% |
||||
Set-up Time |
≤2S (230VAC input, Full load); ≤4S (120VAC input, Full load) |
|||||
Hold up Time |
≥10mS (120/230Vac input, Full load) |
|||||
Temperature Coefficient |
±0.03%/℃ |
|||||
Overshoot and Undershoot |
<5.0% |
|||||
INPUT |
VoltageRange |
90Vac~264Vac,120Vdc~370Vdc |
||||
FrequencyRange |
47Hz–63Hz |
|||||
Power Factor(Typical) |
PF>0.98/120VAC PF>0.95/230VAC |
|||||
Efficiency ( Typical) @ 230Vac |
≥84.5% |
≥87% |
≥86.5% |
≥87.5% |
||
AC Current (最大。) |
< 4.5A |
|||||
Inrush Current (Typical) |
<50A@220Vac <30A@110Vac Cold start |
|||||
Leakage Current |
Input—output:≤0.25mA Input—PG:≤3.5mA (input 264Vac, 63Hz) |
|||||
PROTECTION |
Over Load |
27~35A |
14.5~19A |
9.345~13.35A |
7.3~10A |
|
Protection type: Hiccup mode, auto recovery |
||||||
Over power |
324~420W |
358~456W |
336~480W |
350~180W |
||
Protection type: Hiccup mode, auto recovery |
||||||
Short Circuit |
Long-term mode, auto recovery |
|||||
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-20℃~65℃; 20%~90%RH No condensing(refer to the derating curve) |
||||
Storage Temp. & Hum. |
-40℃~85℃; 10%~95%RH No condensing |
|||||
Vibration |
10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X,Y, Z axes |
|||||
SAFETY &EMC (Note 3) |
Safety Standards |
UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 |
||||
Withstand Voltage |
Primary-Secondary: 3.0KVac; ≤10mA .Primary-PG: 1.5KVac; ≤10mA. Secondary-PG: 0.5KVDC;≤10mA. |
|||||
Isolation Resistance |
10中號ohms |
|||||
EMI Conduction&Radiation |
Compliance to EN55022, EN55024, FCC PART 15 Class B |
|||||
EMSImmunity |
Compliance to EN61000-4-2,3,4,5,6,8,11; |
|||||
OTHERS |
MTBF (MIL-HDBK-217F) |
More than 200,000Hrs (25℃, Full load) |
||||
Dimension (L*W*H) |
199×99×50mm |
|||||
Packing |
||||||
Cooling method |
Cooling by forced air (built-in DC fan) |
|||||
NOTE |
1. All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature. 2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 47uF parallel capacitor. 3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |