IKPS-45-S系列,en

模型:IKPS-45-S,en
筆記: Universal AC input/ Full range (90~264Vac)
High Efficiency, long life and high reliability
Output protections: SCP/OVP/ OLP/OPP
Wide operating ambient temperature (-10℃~60℃)
All using 105℃long life electrolytic capacitors.
100% full load burn-in test

MODEL

IKPS-45-S12

IKPS-45-S24

IKPS-45-S48

OUTPUT

DC Output

12V

24V

48V

Rated Current

3.7一個

1.9一個

1一個

Ripple and Noise

Note 2

0~60℃

120mV

120mV

120mV

-10℃~0℃

200mV

200mV

200mV

Voltage ADJ. Range

11.4~13.2V

22.8~26.4V

45.6~52.8V

Voltage Accuracy

±3.0%

線路調整

±1.0%

負載調節

±3.0%

Set-up Time

0.8S @ 230Vac full load

Hold up Time

60mS @ 230Vac full load

Temperature Coefficient

±0.05%/℃

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange Note 3

90Vac~264Vac

FrequencyRange

47Hz-63Hz

Efficiency ( Typical)

220Vac input

82%

85%

86%

AC Current (最大。)

1一個115VAC 0.6一個230VAC

Inrush Current (Typical)

20A@115Vac 45A@230Vac Cold start

Leakage Current

輸入到輸出: 0.25mA ; Input to PG: 3.5mA

PROTECTION

Over Load

3.9~6.2A

2.0~3.2A

1.1~1.56A

Protection type: Hiccup mode, auto recovery

Over Voltage

13.8~16.2V

27.6~32.4V

55.2~64.8V

Protection type: Constant voltage, Auto recovery

Over Power

46.8~75W

48~75W

53~75W

Protection type: Hiccup mode, auto recovery

Shorted Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-10℃~60℃; 20%~90%RH No condensing (refer to the derating curve)

Storage Temp. & Hum.

-25℃~85℃; 10%~95%RH No condensing

SAFETY &EMC

(Note 4)

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Input-Output:3.0KVac/10mA ; Output-PG: 1.5KVac/10mA;Output-PG: 0.5KVdc/10mA

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022 Class B

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load)

Dimension (L*W*H)

101.6×51×28mm

Packing

Cooling method

Cooling by free air convection

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.