IKPS-60系列,en

模型:IKPS-60系列,en
筆記: Universal AC input 90~264Vac
High Efficiency, low power consumption
Output protections: SCP/OVP/ OLP/OPP
Wide operating ambient temperature (-25℃~70℃)
All using 105℃long life electrolytic capacitors.
100% full load burn-in test

MODEL

IKPS-60-5

IKPS-60-12

IKPS-60-15

IKPS-60-24

IKPS-60-48

OUTPUT

DC Output

5.0V

12.0V

15.0V

24.0V

48.0V

Rated Current

8.0一個

4.5一個

3.6一個

2.5 一個

1.25一個

Ripple and Noise

Note 2

0~70℃

<50mV

<120mV

<150mV

<240mV

<240mV

-25℃~0℃

<200mV

<200mV

<150mV

<240mV

<240mV

Voltage ADJ. Range

-5% ~ +10% of rated voltage

Voltage Accuracy

±3.0%

線路調整

±0.5%

負載調節

±2.0%

Set-up Time

1.0S (230Vac input, Full load)

Hold up Time

20mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/℃

Overshoot and Undershoot

<5.0%

INPUT

VoltageRange Note 3

90Vac~264Vac, 127Vdc~370Vdc

FrequencyRange

47Hz-63Hz

Efficiency ( Typical)

81%

84%

84%

86%

87%

AC Current (最大。)

1.5一個

Inrush Current (Typical)

30A@120Vac 60A@230Vac Cold start

Leakage Current

<0.25mA

PROTECTION

Over Load

105%~180% of rated output current, hiccup mode, auto recovery

Over Power

105%~180% of rated output power, hiccup mode, auto recovery

Over Voltage

105%~150%的額定輸出電壓,,en,恆壓,,en,短路,,en,長期模式,,en,環境,,en,經營,,ca,溫度,,en,哼,,en,~90%RH無冷凝,,en,參考降額曲線,,en,儲存溫度,,en,℃〜85℃,,en,~95%RH無冷凝,,en,安全,,en,EMC,,en,安全標準,,en,UL60950-1,,en,ND,,en,埃德,,en,EN60950-1,,zh-CN,耐壓,,en,主次,,en,KVAC,,en,≤,,en,mA .Primary-PG,,en,毫安,,ar,二次PG,,en,KVDC,,en,隔離電阻,,en,≥,,en,M歐姆,,en,EMC排放,,en,符合EN55022,EN55024 ClassB標準,,en,諧波電流,,en,符合EN61000-3-2,-3,,en,EMC抗擾度,,en,符合EN61000-4-2,3,4,5,6,8,11,,en,EN55024,EN61000-6-2重工業水平,,en,其他,,en,MIL-HDBK-217F,,es,超過200,000小時,,en,L * W * H,,en,×51×28.8毫米,,en,冷卻方式,,en,注意,,en,未特別提及的所有參數均在230Vac輸入下測量,,en,額定負載和25℃的環境溫度,,en,通過使用端接有端子的12“雙絞線,在20MHz的帶寬下測量,,en,uF的,,en,uF並聯電容器,,en, Constant voltage

Shorted Circuit

Long-term mode, auto recovery

ENVIRONMENT

Operating amb. Temp. & Hum.

-25℃~70℃; 20%~90%RH No condensing (refer to the derating curve)

Storage Temp. & Hum.

-30℃~85℃; 10%~95%RH No condensing

SAFETY &EMC

(Note 4)

Safety Standards

UL60950-1; EN60950-12006

Withstand Voltage

Primary-Secondary:3.0KVac; 10mA .

Isolation Resistance

100M ohms

EMI Conduction&Radiation

Compliance to EN55022, FCC PRAT15 B Class B

Harmonic Current

Compliance to EN61000-3-2,-3

EMSImmunity

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25℃, Full load) MIL-217 Method 2 Components Stress Method

Dimension (L*W*H)

101.6×50.8×30mm

Packing

Cooling method

Cooling by free air convection

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25℃ of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.

3. The power supply is considered as a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.